:''This article is about the transmission of electrical power to public transport vehicles. For transmission of bulk electrical power to general consumers, see
Electric power transmission. For powerlines mounted on pylons, see
Overhead powerline''
'Overhead lines' or 'overhead wires' are used to transmit
electrical energy to
trams,
trolleybuses or
trains at a distance from the energy supply point. These overhead lines are known variously as
★ 'OCS' ('overhead contact system' – US & Europe, except UK)
★ 'OLE' or 'OHLE' ('overhead line equipment' – UK)
★ 'OHW' ('overhead wiring' – AUS) or
★ 'Catenary' (somewhat inaccurately).
For the purposes of this article the generic term ''overhead line'' has been used.
Overhead line is designed on the principle of one or more overhead wires situated over
rail tracks, raised to a high electrical potential by connection to feeder stations at regular intervals. The feeder stations are usually fed from a
high-voltage electrical grid.
Overview
Electric trains that collect their current from overhead line system use a device such as
pantograph,
bow collector, or
trolley pole. The current collection device presses against the underside of the lowest wire of an overhead line system, which is called a 'contact wire'. The current collectors are electrically conductive, and allow current to flow through to the transformer of the train or tram, and back to the feeder station via the steel wheels and one or both running rails of the track.
Diesel trains may pass along these tracks without affecting the overhead line, although
overhead clearance may be an issue.
Construction
Because they run on rubber wheels running on pavement rather than steel wheels running on steel rails,
trolleybuses must have a second trolley pole contacting a second wire to return the current to the power system.
To achieve good high speed current collection, it is necessary to keep the contact wire geometry within defined limits throughout the length of the overhead line. It is usually achieved by supporting the contact wire from above by means of a second wire, known variously as the 'messenger wire' (US & Europe) or 'catenary' (UK & Canada). This wire is allowed to follow the natural path of a wire strung between two points, which is known as a catenary curve, thus the use of ''
catenary'' to describe this wire or sometimes the whole system. This wire is attached to the contact wire at regular intervals by vertical wires known as 'droppers' or 'drop wires'. In this way the contact wire is effectively supported at numerous points. The messenger wire is supported regularly at structures, either by means of a
pulley, link, or
clamp. The whole system is then subjected to a mechanical
tension. The messenger wire is usually pulled slightly to the left and right by successive supports, so that the contact wire slides from side to side on the pantograph as the vehicle moves along (if it did not then it would tend to wear a groove in the pantograph's carbon insert). Such a system, with a single supporting wire, is known as 'simple equipment'.
When overhead line systems were first conceived, good current collection was not possible at high speed using a single supporting wire. Two additional types of equipment were developed to combat this problem. 'Stitched equipment' used an additional wire at each support structure, which was terminated either side to the messenger wire. 'Compound equipment' used a second support wire, known as the 'auxiliary', running the whole length of the overhead line between the messenger wire and the contact wire. Droppers are provided to support the auxiliary from the messenger wire, and additional droppers support the contact wire from the auxiliary.
The dropper wires usually only provide physical support of the contact wire, and do not join the catenary and contact wires electrically. Separate wires are provided for this function.
Another reason to use an auxiliary wire is that such a wire could be constructed of a more conductive but less wear-resistant metal, increasing the efficiency of power transmission.
For
tramways there often is just a simple contact wire and no messenger wire.
Tensioning
For medium and high speeds the wires are generally tensioned by means of weights, or occasionally by hydraulic tensioners. Either method is known as 'auto-tensioning' ('AT'), and ensures that the tension in the equipment is virtually independent of temperature. Tensions are typically between 9 and 20
kN per wire.
For low speeds and in tunnels where temperatures are constant, 'fixed termination' ('FT') equipment may be used, with the wires terminated directly on structures at each end of the overhead line. Here the tension is generally about 10 kN. This type of equipment will sag on hot days and hog on cold days.
Where AT is used, there is a limit to the continuous length of overhead line which may be installed. This is due to the change in the position of the weights with temperature as the overhead line expands and contracts. This movement is proportional to the 'tension length', i.e. the distance between anchors. This leads to the concept of maximum tension length. For most 25 kV OHL equipment in the UK the maximum tension length is 1970 m.
An additional issue with AT equipment is that, if balance weights are attached to each end, the whole tension length will be free to move along track. Therefore, a 'mid-point anchor' ('MPA') is introduced close to the centre of the tension length to restrict movement. MPAs are often fixed to low bridges.
Therefore a tension length can be seen as a fixed centre point with the two half tension lengths expanding and contracting with temperature.
Breaks

Neutral Section Indication Board used on railways in the
UK
To allow maintenance to sections of the overhead line without having to turn off the entire system, the overhead line system is broken into electrically separated portions known as 'sections'. Sections often correspond with tension lengths as described above. The transition from section to section is known as a 'section break' and is set up so that the
locomotive's pantograph is in continuous contact with the wire.
For bow-collectors and pantographs, this is done by having two contact wires run next to each other over a length about four wire supports: a new one dropping down and the old one rising up until the pantograph smoothly transfers from one to the next. The two wires never touch (although the bow-collector/pantograph is briefly in contact with both wires). In normal service the two sections are electrically connected (to different substations if at or near the halfway mark between them), but this can be broken for servicing.
On overhead wires designed for trolley poles this is done by having a neutral section between the wires, but this requires an insulator. The driver of the
tram or
trolleybus must turn off the power when the trolley pole passes through to prevent arcing causing damage to the insulator.
Sometimes on a larger electrified railway, tramway or trolleybus system it is necessary to power different areas of track from different power grids, the synchronisation of the phases of which cannot be guaranteed. (Indeed, sometimes the sections are even powered with different voltages or frequencies.) There may be mechanisms for having the grids synchronised on a normal basis, but events may cause desynchronisation. This is no problem for DC systems, but for AC systems it would be quite undesirable to connect two unsynchronised grids together, even momentarily. A normal section break is insufficient to guard against this since the pantograph briefly connects both sections.
Instead, a 'phase break' or neutral section is used. This consists of two section breaks back-to-back so that there is a short section of overhead line that belongs to neither grid. If the two grids are synchronised, this stretch of line is energised (by either supply) and trains run through it normally. If the two supplies are not synchronised, the short isolating section is disconnected from the supplies, leaving it electrically dead, ensuring that the two grids cannot be connected to each other.
The sudden loss of power over the phase break would jar the train if the locomotive was at full throttle, so special signals are set up to warn the crew. When synchronization is lost and the phase break is deenergised, the train's operator must put the controller (throttle) into neutral and coast through an isolated phase break section.
On the
Pennsylvania Railroad, phase breaks were indicated to train crews by a metal sign hung from the overhead with the letters PB on it, created by holes drilled in the metal. When the phase break was "dead", a signal consisting of eight lit lights in a circular pattern indicated this to the crew.
Crossings

An annotated version of the above.
Blue = tram conductor
Green = trolley bus wires
Yellow = insulated trough
Trams draw their power from a single
overhead wire at about 500 to 750
V above
earth, while
trolleybuses draw their power from two overhead wires (powered at similar voltage). Because of that, at least one of the trolleybus wires must be insulated from tram wires. This is usually solved in the following way: the trolleybus wires run continuously through the crossing. The tram
conductors are slung a few centimetres lower than the trolleybus wires. Close to the junction on each side, the wire merges into a solid bar which is angled to run parallel to the trolleybus wires for about half a metre. Another bar similarly angled at its ends is hung between the trolleybus wires. This is electrically connected above to the tram wire's
catenary cable. The tram's pantograph bridges the gap between the different conductors, providing it with a continuous pickup.
Where the tram wire crosses, the trolleybus wires are protected by an inverted trough of
insulating material extending 20 or 30 mm below the level of the trolleybus wires. The tram pantograph or bow collector raises the conductor wire a little as it passes under. These troughs are presumably to limit how far it can do that and to provide a backstop to prevent the tram pantograph or bow collector ever touching the trolleybus wires.
Several cities use the above system. Until 1946 there was a level crossing in
Stockholm,
Sweden between the
railway south of Stockholm Central Station and a
tramway line. The tramway operated on 600-700 V DC and the railway operated on
15 kV AC. Some crossings between tramway/light rail and railways are still alive in Germany. In
Zürich, Switzerland the
VBZ trolleybus line 32 has a level crossing with the 1200V
DC railway to mount
Uetliberg; at many places in the town trolleybus lines cross the tramway. In the Swiss village Suhr the tramway WSB operating at 1200V DC crosses the SBB line on
15 kV AC. In some cities,
trolleybuses and
trams have shared the same positive (feed) wire. In such cases a normal trolleybus frog can be used.
Another system that has been used is to coincide section breaks with the crossing point so that the crossing is electrically dead.
Australia
Many cities had trams and trolleybuses both using trolley pole current collection. They used insulated crossovers which required tram drivers to put the controller into neutral and coast through. Trolleybus drivers had to either lift off the accelerator or switch to auxiliary power.
In
Melbourne,
Victoria tram drivers are still required to put the controller into neutral and coast through section insulators, this being indicated to drivers by insulator markings between the rails.
Melbourne also has another interesting issue - crossings between electrified suburban railways and tram lines at grade. There are four of these
level crossings through the systems and each requires complex switching arrangements to separate the operation of 1500 V DC overhead for the railway and 650 V DC for the trams. This is called an
overhead square.
[1] Proposals have been put forward which would eventually see most or all of these crossings grade separated or the tram routes diverted.
Germany

A twisting pylon of a single phase AC 110 kV power line near Bartholomä in Germany. Lines of this type are used in Germany to supply electric railways with single phase AC with 16.7 hertz
In
Germany there are special overhead power lines for single phase AC traction current with a frequency of 16.7 hertz. Most of these lines, which are all operated with a voltage of 110 kV have four conductor cables for two circuits. As a rule at traction current lines, the single-level arrangement of the
conductor cables is used. A traction current pylon is a
pylon with at least carry one
electric circuit for traction current. For traction current lines with four circuits (eight conductor cables) frequently two-level arrangements of conductors are used, at which one crossbar carries four conductor cables. For traction current lines used for supplying new high-speed rail tracks, three-level arrangements of conductors are used. Thereby are on the lowest crossbar four, and on the upper crossbars two, conductor cables mounted. The three-level arrangement is also used for traction current lines with 6 electric circuits (12 conductor cables).
There are further, in particular for the power supply of
rapid transit railways operated with alternating current, overhead line pylons with crossbars for 110 kV traction current powerlines above the contact wire in use. There are also pylons that carry electric circuits for traction current and for three-phase alternating current of the public power grid.
Greece
In
Athens there are two crossings between overhead tram and trolleybus wires. These crossings are at the junction of Vas. Amalias Avenue with Vas. Olgas Avenue, and the junction of Ardittou Street with Athanasiou Diakou Street. They use the above-mentioned solution for crossing tram and trolleybus wires.
Additionally, for about one year (from the opening of the tram system in the summer of 2004 until mid-2005), trams and trolleybuses with direction to Pagrati shared the same exclusive lane on the far right side of Vas. Olgas Avenue (which is about 400 m long); this required tram and trolleybus wires to coexist side-by-side above a very narrow lane of road. To solve this problem, the trolleybus wires were placed on the far right of the lane, rendering it impossible for the tram's (very wide) pantograph to come into contact with them. As a side-effect, however, trolleybus drivers were required to employ much greater caution on this stretch of road, and drive very slowly through Vasilisis Olgas Avenue, owing to the trolleybus collectors being extended to their limits under this arrangement. Finally, a change of route for trolleybuses was implemented in mid-2005, avoiding Vas. Olgas Avenue completely, and ending this difficult coexistence.
Multiple overhead lines
There are and were some railways which used two and even three overhead lines, usually to carry
three-phase current to the trains. Nowadays, three phase AC-current is used only on the
Gornergrat Railway and
Jungfraujoch Railway in Switzerland, the Petit Train de
La Rhune in France and the
Corcovado Rack Railway in Brasil; until 1976, it was widely used in Italy. On these railways the two conductors of the overhead lines are used for two different phases of the three-phase AC, while the rail was used for the third phase. The neutral was not used.
Some three-phase AC railways used three overhead wires. These were an experimental railway line of Siemens in Berlin-Lichtenberg in 1898 (length: 1.8 kilometres), the military railway between Marienfelde and Zossen between 1901 and 1904 (length: 23.4 kilometres) and an 800-metre-long section of a coal railway near Cologne, between 1940 and 1949.
On DC systems bipolar overhead lines were sometimes used to avoid
galvanic corrosion of metallic parts near the railway. An example of a railway run with DC using two overhead lines was the
Chemin de fer de la Mure.
All systems of multiple overhead lines have the disadvantage of high risk of short circuits at switches and therefore tend to be impractical in use, especially when high voltages are used or when trains run through the points at high speed.
Overhead catenary

Overhead feeding rail, in the RER C trenches and tunnels in central Paris

Compound catenary equipment
of
JR West
A catenary is a system of overhead
wires used to supply
electricity to a
locomotive,
streetcar, or
light rail vehicle which is equipped with a
pantograph.
Unlike simple
overhead wires, in which the uninsulated wire or
cable is attached by clamps to closely spaced crosswires, themselves supported by line poles, catenery system use at least two wires. One wire, called the catenary wire or the messenger wire, is hung at a specific tension value in the shape of a mathematical
catenary between line structures. A second wire is held in
tension by the messenger wire, to which it is attached at frequent intervals by
clamps and connecting wires. The second wire is straight and level, parallel to the
rail tracks, suspended over it as the roadway of a
suspension bridge is over water.
Simple wire installations are common in light rail applications, especially on
city streets, while more expensive catenery systems are especially suited to high-speed operations.
The
Northeast Corridor in the
United States features electrified catenary over a 600-mile or 1000 km distance between
Boston,
Massachusetts and
Washington, D.C., providing power for
Amtrak's high-speed
Acela Express and other trains. Several
commuter rail agencies, including
MARC,
SEPTA,
NJ Transit,
Metro-North utilize the catenary to provide local service along the Northeast Corridor.
The situation in
Cleveland, Ohio is a little out of the ordinary. The
light rail system uses overhead lines as expected. However, the
heavy rail system also uses overhead lines instead of a
third rail. Historically this is due to an ordinance intended to limit air pollution from the large number of trains passing through the city en route from New York to Chicago. Trains would switch locomotives at the
Collinwood Rail Yards about 10 miles east or else reroute to the south of the city. Consequently, both light and heavy rail systems are able to share trackage for about three miles (5 km)along the red-line to
Cleveland Hopkins Airport.
See also
★
Bow collector
★
Pantograph
★
Trolley pole
★
Frank J. Sprague
★
Lineman
★
Metro-North Railroad, a US commuter railway serving
New York and
Connecticut, in which some parts are powered by overhead wires, some by a third rail, and some by diesel engines.