Discover

RELATIVE STATIC PERMITTIVITY

(Redirected from Dielectric constant)
Relative static permittivities of some materials at room temperature
Material Dielectric constant
Vacuum 1 (by definition)
Air 1.00054
Teflonâ„¢ 2.1
Polyethylene 2.25
Polystyrene 2.4–2.7
Paper 3.5
Silicon dioxide 3.7
Concrete 4.5
Pyrex (glass) 4.7 (3.7–10)
Rubber 7
Diamond 5.5–10
Salt 3–15
Graphite 10–15
Silicon 11.68
Methanol 30
Furfural 42.0
Glycerol 47–68
Water 88–80.1–55.3–34.5
(0–20–100–200 °C)
Hydrofluoric acid 83.6 (0 °C)
Formamide 84.0 (20 °C)
Sulfuric acid 84–100
(20–25 °C)
Hydrogen peroxide 128 aq–60
(−30–25 °C)
Hydrocyanic acid 158.0–2.3
(0–21 °C)
Titanium dioxide 86–173
Strontium titanate 310
Barium strontium titanate 15 nc–500
Barium titanate 90 nc–1250–10,000
(20–120 °C)
(La,Nb):(Zr,Ti)PbO3 500,6000

The 'relative static permittivity' (or 'static relative permittivity') of a material under given conditions is a measure of the extent to which it concentrates electrostatic lines of flux. It is the ratio of the amount of stored electrical energy when a potential is applied, relative to the permittivity of a vacuum. The relative static permittivity is the same as the relative permittivity evaluated for a frequency of zero.
The relative static permittivity is represented as ''εr'' or sometimes kappa or ''K'' or Dk. It is defined as
: arepsilon_{r} = rac{ arepsilon_{s}}{ arepsilon_{0}}
where ''εs'' is the static permittivity of the material, and ''ε0'' is vacuum permittivity. (The relative permittivity is the complex frequency-dependent arepsilon(omega) / arepsilon_0, which gives the static relative permittivity for omega=0.)
Another term for the relative static permittivity is the 'dielectric constant', or the 'relative dielectric constant', or the 'static dielectric constant'. These terms, while they remain very common, are ambiguous and have been deprecated by some standards organizations.[1][2] The reason for the potential ambiguity is twofold. First, some older authors used "dielectric constant" or "absolute dielectric constant" for the absolute permittivity arepsilon rather than the relative permittivity.[3] Second, while in most modern usage "dielectric constant" refers to a relative permittivity[4], it may be either the static or the frequency-dependent relative permittivity depending on context.
By definition, the relative permittivity of vacuum, where arepsilon = arepsilon_0, is equal to 1.
The static relative permittivity of a medium is related to its static electric susceptibility, chi_e by
: arepsilon_r = 1 + chi_e.
in SI units.

Contents
Measurement
Practical relevance
Chemical applications
See also
References
External links

Measurement


The relative static permittivity ''εr'' can be measured for static electric fields as follows: first the capacitance of a test capacitor ''C0'' is measured with vacuum between its plates. Then, using the same capacitor and distance between its plates the capacitance ''Cx'' with a dielectric between the plates is measured. The relative dielectric constant can be then calculated as
: arepsilon_{r} = rac{C_{x}} {C_{0}}.
For time-varying electromagnetic fields, this quantity becomes frequency dependent and in general is called ''relative permittivity''.

Practical relevance


The dielectric constant is an essential piece of information when designing capacitors, and in other circumstances where a material might be expected to introduce capacitance into a circuit. If a material with a high dielectric constant is placed in an electric field, the magnitude of that field will be measurably reduced within the volume of the dielectric. This fact is commonly used to increase the capacitance of a particular capacitor design. The layers beneath etched conductors in Printed Circuit Boards (PCBs) also act as dielectrics.
Dielectrics are used in RF transmission lines. In a coaxial cable, polyethylene can be used between the center conductor and outside shield. It can also be placed inside waveguides to form filters. Optical fibers are examples of ''dielectric waveguides''. They consist of dielectric materials that are purposely doped with impurities so as to control the precise value of ''εr'' within the cross-section. This controls the refractive index of the material and therefore also the optical modes of transmission. However, in these cases it is technically the relative permittivity that matters, as they are not operated in the electrostatic limit.

Chemical applications


The dielectric constant of a solvent is a relative measure of its polarity. For example, water (very polar) has a dielectric constant of 80.10 at 20 °C while n-hexane (very non-polar) has a dielectric constant of 1.89 at 20 °C.1 This information is of great value when designing separation, sample preparation and chromatography techniques in analytical chemistry.

See also



Dielectric strength

Low-k

High-k

References


1.
2. IEEE Standard Definitions of Terms for Radio Wave Propagation IEEE Standards Board
3. Fundamental Electromagnetic Theory, , Ronold W. P., King, Dover, ,
4. Classical Electrodynamics, 3rd edition, , John David, Jackson, Wiley, ,

1) D.R. Lide, Ed. CRC Handbook of Chemistry and Physics, 85th Ed. CRC Press. Boca Raton. 2004. pg. 8-141.

External links



Dielectric Constants of Materials

This article provided by Wikipedia. To edit the contents of this article, click here for original source.